Buyer RFQ Guide · Planar Transformers and High-Current Inductors

What Information Is Required for a Custom Planar Transformer or High-Current Inductor RFQ?

Direct answer: send the converter topology, complete operating points and waveforms, electrical targets with their test conditions, insulation system, terminal map, mechanical envelope, cooling boundary, project stage and validation or acceptance plan. A power rating, inductance value or “rated current” alone is not enough to produce a defensible custom design.

This checklist turns a free-text inquiry into an engineering input package. It is intended for early feasibility review, quotation and design verification planning—not as a universal catalog specification.

PROMAGTECH product photograph with the custom magnetics RFQ checklist cover text
Approved PROMAGTECH product photograph used as the cover for this RFQ checklist. The photograph is not a performance claim; the article defines separate input requirements for planar transformers and high-current inductors.
Evidence boundary: the field groups below are based on real PROMAGTECH development reviews, existing public engineering cases and common custom-magnetics request forms. They define the information needed to start engineering. They do not claim that every requested voltage, current, frequency, insulation level, size or validation state is already achieved.

The one-page RFQ readiness summary

Input blockMinimum informationWhy it changes the design
Application and topologyConverter function, topology, phase count, bidirectional mode, isolation requirement and magnetic component roleThe same power level can require different flux swing, current waveform, leakage, insulation and control margin.
Operating-point tableMinimum, nominal and maximum input; output voltage/current; power; switching and resonant frequency; duty or modulation range; overload and startupWorst electrical stress and worst thermal stress often occur at different operating points.
WaveformsVoltage waveform, average/RMS/peak current, ripple magnitude and frequency, transient duration and repetitionRMS current drives copper heating; peak current and flux drive saturation margin; ripple drives AC copper and core loss.
Electrical targetsInductance or turns ratio, magnetizing and resonant-inductance boundary, DCR at a stated temperature, leakage or capacitance target, tolerances and test conditionsA number without current, frequency, amplitude, temperature, terminal definition and equivalent-circuit mode is not comparable.
Insulation systemWorking and transient voltage, hipot or PD requirement, insulation class, pollution/material group if specified, creepage, clearance and isolation architectureInsulation consumes winding window, changes leakage and capacitance, and determines materials and process controls.
Mechanics and coolingMaximum L × W × H, keep-outs, mounting, terminal map, vibration constraints, ambient/coolant range, airflow, cold plate or potting boundaryThermal resistance and manufacturable conductor geometry depend on the real assembly boundary.
Project and evidence stageConcept, simulation, first sample, DVP, pilot or released production; sample quantity; required reports; acceptance ownerThe quotation must separate design estimates from sample verification and production acceptance.

Custom planar transformer RFQ checklist

For a custom planar transformer, include the shared inputs above plus the following transformer-specific items:

  1. Topology and magnetic role: LLC, CLLC, DCX, PSFB, flyback or another topology; state whether leakage is parasitic, controlled as part of Lr, or paired with an external resonant inductor.
  2. Voltage and power matrix: input range, output range, nominal and corner power, startup/pre-bias, burst or skip mode, overload and any reverse-power mode.
  3. Frequency definition: nominal switching frequency, allowed range, resonant frequency and any frequency sweep used for control.
  4. Turns and inductance boundary: desired turns ratio or secondary voltage, target Lm, target Lr, allowed leakage contribution, and the side to which each value is referred.
  5. Winding and terminal map: series/parallel connection, center taps, matrix cells, current sharing, PCB layer limits, copper thickness, via or busbar constraints, and exact pin numbering.
  6. Capacitance and EMI boundary: interwinding-capacitance target if controlled, shield strategy, primary-secondary dv/dt, common-mode-current concern and measurement method.
  7. Insulation and safety: reinforced/basic/functional insulation, working voltage, surge or transient, hipot, partial-discharge target if required, creepage, clearance and material restrictions.
  8. Mechanical and thermal boundary: maximum height, footprint, mounting, heat-spreader or cold-plate interface, airflow, potting, nearby heat sources and allowed hot-spot temperature.
  9. Verification definition: loss or efficiency points, temperature-rise condition, hipot/PD, leakage and capacitance test method, sample count and acceptance criteria.
Real-review lesson: PROMAGTECH's public leakage-inductance evidence note compares a 1 MHz / 3.3 kW matrix design with a lower-power planar reference. The two records use different shorted terminals, test frequency, amplitude and reference-side definitions. That is why “leakage inductance required” is not a complete RFQ line.

Custom high-current inductor RFQ checklist

For a custom high-current flat-wire inductor, do not collapse the current requirement into one catalog number. Include:

  1. Topology and phase count: boost, buck, PFC, DC-link filter, output filter, differential-mode choke or another function; state interleaving and current-sharing method.
  2. Current set: average, RMS, peak, peak duration, ripple peak-to-peak, ripple frequency, overload profile and any fault-current requirement.
  3. Inductance definition: small-signal inductance, loaded inductance at a stated DC current, frequency, amplitude and temperature, plus the allowed roll-off or tolerance.
  4. Saturation criterion: define whether the limit is a percentage inductance drop, a peak-flux boundary or another customer method. “Isat” without a criterion is ambiguous.
  5. DCR definition: target and maximum DCR, conductor temperature or correction reference, terminal-to-terminal method and whether lead or busbar resistance is included.
  6. Applied voltage and loss inputs: voltage waveform, duty or modulation, ripple spectrum and switching edges needed to estimate core and AC copper loss.
  7. Core and acoustic constraints: material restrictions, air-gap or distributed-gap preference, audible-noise or vibration requirement and nearby magnetic coupling concerns.
  8. Mechanical, terminals and cooling: envelope, mounting, flat-wire orientation, terminal plating and joint, airflow or cold-plate interface, potting and allowable hot spot.
  9. Verification definition: DC-bias curve, DCR, loss or temperature-rise method, thermal soak time, sample count, dielectric tests and released acceptance limits.

The public 120 V / 40 A / 66 kHz inductor case and 11 kW totem-pole PFC case show why loaded inductance, DCR, waveform, core arrangement and thermal boundary must be reviewed separately.

Evidence states to put in the quotation

StateWhat may be reportedWhat must remain open
Design inputCustomer target, operating point and proposed acceptance methodFeasibility, margin and achieved result
CalculatedFirst-pass turns, flux, DCR, loss and thermal estimates with assumptionsFinished assembly parasitics, sample spread and production capability
SimulatedField, circuit or thermal model result with model boundary and mesh/material assumptionsCorrelation to physical samples
Sample measuredInstrument, fixture, sample ID, revision, condition and individual resultContinuous operation and lot capability unless separately tested
Continuous / thermal verifiedDefined duration, ambient or coolant, airflow/interface, waveform and stabilized temperaturesProduction acceptance unless released criteria exist
Production acceptedReleased drawing, approved test method, tolerance/capability evidence and acceptance ownerNo upgrade beyond the approved model, condition and revision

Copy-and-paste RFQ template

Component type: planar transformer / high-current inductor
Project stage: concept / simulation / sample / DVP / pilot / production
Application and topology:
Vin / Vout / power operating points:
Switching and resonant frequency range:
Voltage waveform:
Average / RMS / peak / ripple current:
Electrical targets and test conditions:
Insulation / hipot / PD / creepage / clearance:
Maximum envelope and terminal map:
Cooling boundary and temperature limits:
Sample quantity, required reports and acceptance criteria:
Attachments: circuit excerpt, waveforms, drawing or STEP, pin map, validation specification

Recommended files for the first review

For process and test context, review PROMAGTECH's manufacturing and verification evidence and the temperature-rise test method.

Method references

Public custom-magnetics request forms from Würth Elektronik and Vishay collect the same classes of topology, electrical, mechanical, insulation and project inputs. PROMAGTECH uses those public sources only as general method references; company claims and project conclusions remain tied to PROMAGTECH's own evidence.

Frequently asked questions

What information is required for a custom planar transformer RFQ?

Provide topology, input and output voltage ranges, power operating points, switching and resonant frequencies, turns ratio or secondary-voltage target, Lm and Lr boundary, terminal map, insulation system, mechanical envelope, cooling boundary, sample stage and acceptance tests.

What information is required for a custom high-current inductor RFQ?

Provide topology and phase count, average, RMS, peak and ripple current, applied voltage waveform, switching frequency, target inductance at the stated current and temperature, DCR test temperature, saturation or roll-off criterion, insulation, mechanical envelope, cooling boundary and validation plan.

Is rated current alone enough to select a custom inductor?

No. Rated current can refer to a thermal limit, an inductance roll-off limit or a catalog convention. A usable RFQ separates average, RMS, peak and ripple current and states the allowed temperature rise and loaded-inductance criterion.

Why must the cooling boundary be included in a magnetics RFQ?

The same magnetic component can reach different temperatures in still air, forced air, cold-plate contact or a potted enclosure. Cooling method, ambient or coolant temperature, airflow or interface condition and allowed hot-spot temperature belong in the design input.

Can a calculated value become the production acceptance limit?

No. Calculated and simulated values guide the design. A production limit needs a released drawing, defined test method, correlated sample data, tolerance or capability review and customer-approved acceptance criteria.

Which files help PROMAGTECH review an RFQ efficiently?

Send a circuit excerpt or topology diagram, operating-point table, current and voltage waveforms, mechanical envelope or STEP drawing, pin or terminal map, insulation requirement, cooling description and the required sample and production validation tests. Customer identity and unrelated confidential files are not needed for an initial technical screen.

Request a project-specific engineering review

Use the template above and attach only the circuit excerpt, waveforms and mechanical information needed for the initial review. PROMAGTECH will keep design targets, calculations, simulations, sample results, continuous tests and production acceptance as separate states.

Send RFQ ParametersPlanar Transformer CapabilityFlat-Wire Inductor Capability

Published 2026-11-17. Engineering content by Zhang Yong, SHENZHEN PROMAGTECH CO., LTD. Contact: zyong@promagtech.cn · +86 13537658938.