The one-page RFQ readiness summary
| Input block | Minimum information | Why it changes the design |
|---|---|---|
| Application and topology | Converter function, topology, phase count, bidirectional mode, isolation requirement and magnetic component role | The same power level can require different flux swing, current waveform, leakage, insulation and control margin. |
| Operating-point table | Minimum, nominal and maximum input; output voltage/current; power; switching and resonant frequency; duty or modulation range; overload and startup | Worst electrical stress and worst thermal stress often occur at different operating points. |
| Waveforms | Voltage waveform, average/RMS/peak current, ripple magnitude and frequency, transient duration and repetition | RMS current drives copper heating; peak current and flux drive saturation margin; ripple drives AC copper and core loss. |
| Electrical targets | Inductance or turns ratio, magnetizing and resonant-inductance boundary, DCR at a stated temperature, leakage or capacitance target, tolerances and test conditions | A number without current, frequency, amplitude, temperature, terminal definition and equivalent-circuit mode is not comparable. |
| Insulation system | Working and transient voltage, hipot or PD requirement, insulation class, pollution/material group if specified, creepage, clearance and isolation architecture | Insulation consumes winding window, changes leakage and capacitance, and determines materials and process controls. |
| Mechanics and cooling | Maximum L × W × H, keep-outs, mounting, terminal map, vibration constraints, ambient/coolant range, airflow, cold plate or potting boundary | Thermal resistance and manufacturable conductor geometry depend on the real assembly boundary. |
| Project and evidence stage | Concept, simulation, first sample, DVP, pilot or released production; sample quantity; required reports; acceptance owner | The quotation must separate design estimates from sample verification and production acceptance. |
Custom planar transformer RFQ checklist
For a custom planar transformer, include the shared inputs above plus the following transformer-specific items:
- Topology and magnetic role: LLC, CLLC, DCX, PSFB, flyback or another topology; state whether leakage is parasitic, controlled as part of Lr, or paired with an external resonant inductor.
- Voltage and power matrix: input range, output range, nominal and corner power, startup/pre-bias, burst or skip mode, overload and any reverse-power mode.
- Frequency definition: nominal switching frequency, allowed range, resonant frequency and any frequency sweep used for control.
- Turns and inductance boundary: desired turns ratio or secondary voltage, target Lm, target Lr, allowed leakage contribution, and the side to which each value is referred.
- Winding and terminal map: series/parallel connection, center taps, matrix cells, current sharing, PCB layer limits, copper thickness, via or busbar constraints, and exact pin numbering.
- Capacitance and EMI boundary: interwinding-capacitance target if controlled, shield strategy, primary-secondary dv/dt, common-mode-current concern and measurement method.
- Insulation and safety: reinforced/basic/functional insulation, working voltage, surge or transient, hipot, partial-discharge target if required, creepage, clearance and material restrictions.
- Mechanical and thermal boundary: maximum height, footprint, mounting, heat-spreader or cold-plate interface, airflow, potting, nearby heat sources and allowed hot-spot temperature.
- Verification definition: loss or efficiency points, temperature-rise condition, hipot/PD, leakage and capacitance test method, sample count and acceptance criteria.
Custom high-current inductor RFQ checklist
For a custom high-current flat-wire inductor, do not collapse the current requirement into one catalog number. Include:
- Topology and phase count: boost, buck, PFC, DC-link filter, output filter, differential-mode choke or another function; state interleaving and current-sharing method.
- Current set: average, RMS, peak, peak duration, ripple peak-to-peak, ripple frequency, overload profile and any fault-current requirement.
- Inductance definition: small-signal inductance, loaded inductance at a stated DC current, frequency, amplitude and temperature, plus the allowed roll-off or tolerance.
- Saturation criterion: define whether the limit is a percentage inductance drop, a peak-flux boundary or another customer method. “Isat” without a criterion is ambiguous.
- DCR definition: target and maximum DCR, conductor temperature or correction reference, terminal-to-terminal method and whether lead or busbar resistance is included.
- Applied voltage and loss inputs: voltage waveform, duty or modulation, ripple spectrum and switching edges needed to estimate core and AC copper loss.
- Core and acoustic constraints: material restrictions, air-gap or distributed-gap preference, audible-noise or vibration requirement and nearby magnetic coupling concerns.
- Mechanical, terminals and cooling: envelope, mounting, flat-wire orientation, terminal plating and joint, airflow or cold-plate interface, potting and allowable hot spot.
- Verification definition: DC-bias curve, DCR, loss or temperature-rise method, thermal soak time, sample count, dielectric tests and released acceptance limits.
The public 120 V / 40 A / 66 kHz inductor case and 11 kW totem-pole PFC case show why loaded inductance, DCR, waveform, core arrangement and thermal boundary must be reviewed separately.
Evidence states to put in the quotation
| State | What may be reported | What must remain open |
|---|---|---|
| Design input | Customer target, operating point and proposed acceptance method | Feasibility, margin and achieved result |
| Calculated | First-pass turns, flux, DCR, loss and thermal estimates with assumptions | Finished assembly parasitics, sample spread and production capability |
| Simulated | Field, circuit or thermal model result with model boundary and mesh/material assumptions | Correlation to physical samples |
| Sample measured | Instrument, fixture, sample ID, revision, condition and individual result | Continuous operation and lot capability unless separately tested |
| Continuous / thermal verified | Defined duration, ambient or coolant, airflow/interface, waveform and stabilized temperatures | Production acceptance unless released criteria exist |
| Production accepted | Released drawing, approved test method, tolerance/capability evidence and acceptance owner | No upgrade beyond the approved model, condition and revision |
Copy-and-paste RFQ template
Component type: planar transformer / high-current inductorProject stage: concept / simulation / sample / DVP / pilot / productionApplication and topology:Vin / Vout / power operating points:Switching and resonant frequency range:Voltage waveform:Average / RMS / peak / ripple current:Electrical targets and test conditions:Insulation / hipot / PD / creepage / clearance:Maximum envelope and terminal map:Cooling boundary and temperature limits:Sample quantity, required reports and acceptance criteria:Attachments: circuit excerpt, waveforms, drawing or STEP, pin map, validation specificationRecommended files for the first review
- a cropped circuit or topology diagram showing only the magnetic component and adjacent switching nodes;
- a table of minimum, nominal and maximum operating points;
- current and voltage waveforms, including startup, overload and transient conditions;
- a mechanical envelope, STEP model or dimensioned keep-out drawing;
- a terminal or pin map and the intended series/parallel connection;
- insulation, thermal and validation requirements with the acceptance owner identified.
For process and test context, review PROMAGTECH's manufacturing and verification evidence and the temperature-rise test method.
Method references
Public custom-magnetics request forms from Würth Elektronik and Vishay collect the same classes of topology, electrical, mechanical, insulation and project inputs. PROMAGTECH uses those public sources only as general method references; company claims and project conclusions remain tied to PROMAGTECH's own evidence.
Frequently asked questions
What information is required for a custom planar transformer RFQ?
Provide topology, input and output voltage ranges, power operating points, switching and resonant frequencies, turns ratio or secondary-voltage target, Lm and Lr boundary, terminal map, insulation system, mechanical envelope, cooling boundary, sample stage and acceptance tests.
What information is required for a custom high-current inductor RFQ?
Provide topology and phase count, average, RMS, peak and ripple current, applied voltage waveform, switching frequency, target inductance at the stated current and temperature, DCR test temperature, saturation or roll-off criterion, insulation, mechanical envelope, cooling boundary and validation plan.
Is rated current alone enough to select a custom inductor?
No. Rated current can refer to a thermal limit, an inductance roll-off limit or a catalog convention. A usable RFQ separates average, RMS, peak and ripple current and states the allowed temperature rise and loaded-inductance criterion.
Why must the cooling boundary be included in a magnetics RFQ?
The same magnetic component can reach different temperatures in still air, forced air, cold-plate contact or a potted enclosure. Cooling method, ambient or coolant temperature, airflow or interface condition and allowed hot-spot temperature belong in the design input.
Can a calculated value become the production acceptance limit?
No. Calculated and simulated values guide the design. A production limit needs a released drawing, defined test method, correlated sample data, tolerance or capability review and customer-approved acceptance criteria.
Which files help PROMAGTECH review an RFQ efficiently?
Send a circuit excerpt or topology diagram, operating-point table, current and voltage waveforms, mechanical envelope or STEP drawing, pin or terminal map, insulation requirement, cooling description and the required sample and production validation tests. Customer identity and unrelated confidential files are not needed for an initial technical screen.
Request a project-specific engineering review
Use the template above and attach only the circuit excerpt, waveforms and mechanical information needed for the initial review. PROMAGTECH will keep design targets, calculations, simulations, sample results, continuous tests and production acceptance as separate states.
Send RFQ ParametersPlanar Transformer CapabilityFlat-Wire Inductor CapabilityPublished 2026-11-17. Engineering content by Zhang Yong, SHENZHEN PROMAGTECH CO., LTD. Contact: zyong@promagtech.cn · +86 13537658938.