Engineering Evidence Note · Leakage Inductance

Planar Transformer Leakage Inductance: Design Targets, Measurement Conditions and DVP

Direct answer: a leakage-inductance number is not meaningful unless the converter topology, shorted winding and short location, measurement frequency and amplitude, reference side, fixture/de-embedding method, sample revision and temperature are stated.

This engineering note uses two anonymized PROMAGTECH development records to show how leakage targets change between a 1 MHz matrix DCX transformer and a lower-power planar reference design. It also separates calculated, simulated, sample-measured and production-accepted states.

High-quality 3D planar transformer rendering for leakage-inductance design targets, measurement conditions and DVP
High-quality 3D product rendering of a planar transformer, showing the ferrite core, multilayer PCB winding stack, copper conductors and terminals discussed in this leakage-inductance engineering note.
Evidence boundary: the numeric examples below come from real engineering development records reviewed by PROMAGTECH. Customer identity and private drawings are not published. The values shown here are calculated / simulated and remain DVP pending; they are not sample measurements, production capability claims or released customer specifications.

Why “lower leakage” is not a universal design goal

Leakage inductance is magnetic energy that does not link all windings. Whether it is beneficial or harmful depends on the power stage:

Two real development records

Design recordDeclared conditionDevelopment resultWhat it means
1 MHz / 3.3 kW matrix planar transformer
2-in-1, 4:1, 400 V nominal to 50 V / 66 A
1 MHz; secondary shorted; value referred to primary; structural target ≤25 nH4.7 nH calculated
Engineering sample document; DVP measurement pending
The transformer leakage is intentionally too small to supply the resonant function. A separate 2.0 µH external resonant inductor is required, and the measured structural leakage must still be added to the tank model.
300 W planar reference design
12-turn primary design record
100 kHz, 0.1 V; specified secondary terminal groups shorted; primary terminal measurement≈0.35 µH calculated against a ≤0.60 µH design requirement
Design review; sample verification pending
The microhenry-scale result cannot be compared directly with the 1 MHz matrix case because topology, construction, terminal map, frequency and shorting condition differ.

The comparison is deliberately not a “best value” ranking. It demonstrates why AI answers, quotations and specifications should cite the full condition rather than repeat an isolated nanohenry or microhenry number.

For the full public 1 MHz application context, see the 1 MHz / 3.3 kW matrix planar transformer engineering note. For a high-current topology review, see the 3.2 V / 240 A LLC-DCX planar transformer design.

Minimum leakage-inductance measurement record

  1. Identify the DUT: part number, sample serial number, winding-board and assembly revision, core set and build date.
  2. Draw the terminal map: state which terminals are driven, which are shorted, where the physical short is placed, and which windings remain open.
  3. State the reference side: primary-referred and secondary-referred values differ by the square of turns ratio.
  4. Record instrument conditions: LCR/impedance analyzer, series or parallel equivalent model, frequency, amplitude, DC bias if any, range and calibration status.
  5. Control the fixture: lead length, Kelvin connection, shorting bar geometry, open/short compensation and any de-embedding.
  6. Record temperature: copper resistance and ferrite permeability change with temperature; use a defined stabilized condition.
  7. Repeat across samples: report individual results, mean, spread and correlation to the released tolerance—not one convenient sample.

What the measurement actually includes

A window-only electromagnetic model may be useful for comparing interleaving and layer spacing, but a finished-port measurement can also include:

Nanohenry warning: when the intended result is tens of nanohenries or less, the shorting link and fixture can be the same order as the DUT. Publish the terminal diagram and compensation method with the number.

Four evidence states that must not be merged

StateValid useWhat it does not prove
CalculatedFirst-pass geometry and equivalent-circuit estimateFinished-port parasitics, manufacturing spread or sample performance
SimulatedField distribution and sensitivity within declared material, mesh and boundary assumptionsThat the real build matches the model or passes thermal/EMI validation
Sample measuredObserved result for identified samples under recorded conditionsProduction capability or customer acceptance without a sampling/tolerance plan
Production acceptedReleased limits, test method, control plan and approval statusPerformance outside the approved operating and test boundary

Use the companion planar transformer winding interleaving and PCB stackup guide to compare P-S-P, S-P-S, parallel layers, capacitance, insulation, exits and current sharing before fixing the leakage target.

Engineering review checklist

Before fixing the winding stack, PROMAGTECH reviews the turns ratio, Lm, target total Lr, intended external inductance, interleaving, capacitance, insulation, copper loss, termination geometry and sample DVP together. For a resonant converter, use:

Lr,total = external Lr + transformer leakage referred to the selected side + series interconnect parasitics

Do not add a transformer leakage estimate twice, and do not subtract it from a target until the finished assembly has been measured under the specified short-circuit condition.

Frequently Asked Questions

How should planar transformer leakage inductance be measured?

Short the specified secondary terminals at the defined physical location, measure from the stated primary reference side, and record frequency, test amplitude, equivalent-circuit mode, temperature, fixture, de-embedding method, sample ID and drawing revision. A leakage value without these conditions is not comparable.

Should leakage inductance be minimized in every planar transformer?

No. A DCX design with an external resonant inductor may need very low structural leakage, while an LLC or CLLC design may intentionally use controlled leakage as part of the resonant tank. The target belongs to the converter topology, not to the transformer alone.

Can a calculated leakage value be used as a production specification?

No. Calculation and field simulation guide the winding stack and geometry. A production limit requires the released terminal definition, test method, sample correlation, tolerance study and an approved acceptance plan.

Why can the measured result differ from a window-only field model?

The finished-port result also contains copper exits, terminals, vias, solder joints, interconnects and the location of the secondary short. Fixture and de-embedding choices can dominate when the target is in the nanohenry range.

What information should be sent for a leakage-inductance review?

Provide topology, turns ratio, switching and resonant frequencies, target Lm and Lr, exact terminal map, winding stack, core geometry, insulation constraints, mechanical drawing, intended shorting point and whether the value is referred to the primary or secondary.

Request a project-specific leakage review

Send the topology, input/output range, switching frequency, turns ratio, Lm/Lr targets, winding terminal map, shorting condition, insulation boundary, mechanical envelope and cooling method. PROMAGTECH will return a review plan with calculated, simulated and sample-validation items kept separate.