Planar Transformer Design Guide

Planar Transformer Winding Interleaving and PCB Stackup: How Do You Choose?

A good stack is not simply the one with the lowest calculated leakage. It must also control capacitance, AC loss, current sharing, insulation stress, terminations, tolerance and heat flow.

PROMAGTECH planar transformer CAD rendering for a winding interleaving and PCB stackup decision guide
Existing PROMAGTECH-owned CAD product rendering. It illustrates the component class and visible PCB stack; it is not a sample photograph or proof of a released winding design.

Direct answer

Choose the winding sequence from the converter and isolation boundary, then optimize the whole system—not one parasitic. Interleaving P and S sections usually reduces leakage inductance and AC winding loss, but greater overlap can increase primary-secondary capacitance and common-mode current. Parallel PCB or foil layers can reduce resistance only when current paths, vias, exits and terminals remain symmetric. Freeze the stack only after checking the released mechanical window, insulation system, leakage/Lr allocation, capacitance or EMI limit, hot-spot path and sample-test method.

What P-S-P, S-P-S and split stacks actually change

Candidate patternPotential benefitWhat can go wrong
P-S-P
Primary split around secondary
Short magnetic distance and lower leakage; the higher-turn primary can be divided into single-layer sections.More primary-secondary overlap can increase capacitance; the two primary sections need controlled series connection, polarity and voltage stress.
S-P-S
Secondary split around primary
Useful when the high-current secondary needs short, broad parallel paths and accessible outer surfaces for cooling or termination.Unequal exits, busbars or foil joints can unbalance current; the outer layers may face different thermal and electric-field conditions.
P-S-P-S-P
Higher interleaving degree
Can further reduce window leakage and proximity loss by keeping each section close to the opposing ampere-turns.Capacitance, layer count, tolerance stack, via count and insulation interfaces all increase; assembly errors become more consequential.
Sector or non-overlapCan sharply reduce primary-secondary capacitance and common-mode displacement current.Leakage and copper path length may rise; available winding area, creepage and thermal spreading must be rechecked.

Seven decisions before releasing the PCB stack

1. Freeze the electrical boundary

Define topology, bridge drive, input/output range, turns ratio, switching and resonant frequencies, duty/gain range, RMS and peak current, Lm and whether transformer leakage is part of Lr or must be minimized.

2. Assign turns to real copper sections

Map every turn, layer, series join and parallel branch. Use the winding with the highest turns or strongest proximity-loss risk to decide where splitting provides the most value.

3. Set the capacitance and EMI boundary

Specify an allowable primary-secondary capacitance or common-mode-current target when fast dv/dt matters. Do not approve a low-leakage stack before checking its displacement-current path.

4. Design branch symmetry

Parallel layers need matched copper length, width, thickness, via impedance, exit geometry and terminal connection. Symmetry on a layer drawing is insufficient if the external bus or solder path is unequal.

5. Close insulation and tolerance

Check dielectric thickness, material system, creepage, clearance, margins, core-to-winding insulation, registration, copper-to-edge rules and worst-case accumulated stack height—not nominal fit only.

6. Include exits, vias and terminals

Window-only calculations exclude neck-downs, layer transitions, pins, busbars and the physical shorting location used for leakage measurement. These can dominate a nanohenry-scale result.

7. Correlate calculation to hardware

Measure the released sample revision for DCR, leakage, capacitance, loss, current sharing, temperature and isolation under defined fixtures. Record what is calculated, simulated and measured separately.

Published PROMAGTECH evidence and its boundary

Public recordStack informationEvidence state
3.2 V / 240 A LLC-DCX design exampleTen double-sided 2 oz primary PCBs, eleven parallel 0.20 mm secondary foils, alternating S-P-S-P…-S, five parallel primary branches. The nominal 7.10 mm stack can exceed the available window at worst-case PCB tolerance.Specification-stage calculation. The published AC-loss factor and approximately 1.7 nH window-leakage result exclude end fields, vias, exits and terminals; sample validation remains required.
1 MHz / 3.3 kW matrix planar transformerThe public case requires the PCB stack, current sharing, copper thickness, leakage, capacitance, insulation and cooling to be frozen together.Engineering reference. It does not publish a universal P-S-P or S-P-S stack that should be copied into another converter.
Leakage-inductance design and measurement methodDefines reference side, shorted terminals, frequency, amplitude, fixture and finished-port parasitics.Method plus anonymized development records. DVP status remains separate from calculated targets.

Boundary: The detailed S-P-S-P example is useful because it exposes both the benefit and the tolerance risk. It is not a catalog recipe. A new converter must re-run turns, current density, AC loss, capacitance, insulation and mechanical-fit decisions.

Evidence-state gate

StateStatus for this guideWhat it proves
Design inputsDefined as a required checklistThe decision cannot start until topology, operating points, parasitic limits, insulation, mechanics and cooling are known.
CalculationOne public case citedSpecification-stage loss, stack fit and leakage screening only.
SimulationNot claimed for this new guideNo new electromagnetic or thermal field result is presented.
Sample measurementNot claimedNo new sample leakage, capacitance, loss or temperature result is published.
Continuous thermal validationRequired per projectMust be run on the released winding and assembly under agreed cooling and operating conditions.
Production acceptanceProject-specificRequires the approved drawing, PCB/foil revisions, test method, tolerances, sampling rule and records.

Minimum data for a stackup review

  • Topology, bridge type, input/output range, operating points and control mode
  • Switching/resonant frequencies, turns ratio, Lm and Lr allocation
  • Primary and secondary RMS, peak and ripple currents at worst cases
  • Allowed leakage, measurement reference side and exact shorting condition
  • Maximum interwinding capacitance or common-mode-current/EMI objective
  • Isolation class, working voltage, dielectric test, creepage, clearance and material system
  • Core/window dimensions, maximum height, copper/PCB options, terminals, vias and busbars
  • Cooling interface, ambient, airflow, mounting and validation/acceptance criteria
Send a Planar Transformer Stackup Review

Engineering contact: zyong@promagtech.cn · +86 13537658938. Final values require approved samples and project validation.

Frequently asked questions

Is P-S-P always the best planar transformer stack?

No. P-S-P can reduce leakage and AC winding loss, but the extra primary-secondary overlap can increase interwinding capacitance and common-mode current. The best sequence depends on topology, voltage slew rate, isolation, current paths, resonant-inductance allocation and EMI limits.

When is S-P-S a better starting point?

S-P-S may be useful when the secondary has the higher current and should be split around the primary for shorter parallel current paths or better surface heat extraction. It still requires symmetric exits, polarity control, capacitance review and current-sharing verification.

Does more interleaving always reduce total converter loss?

No. More interleaving can reduce leakage inductance and proximity loss while increasing primary-secondary capacitance, displacement current, layer count, assembly complexity and insulation exposure. Evaluate transformer loss and system EMI together.

How should parallel PCB winding layers be connected?

Use equal electrical length, copper cross-section, via and terminal impedance for each branch, keep the magnetic environment symmetric, and define where the layers join. Verify branch current sharing and hot spots on the released hardware.

Can a calculated planar stack be used as a production release?

No. Calculation and field simulation screen candidate stacks. Production release requires the final PCB and copper revisions, insulation system, measured leakage and capacitance, DCR and loss correlation, thermal validation, tolerances and an approved acceptance plan.

What information is needed for a planar transformer stackup review?

Provide topology, input and output ranges, switching and resonant frequencies, turns ratio, RMS and peak currents, Lm and Lr allocation, isolation class, creepage and clearance, maximum capacitance or common-mode-current limit, mechanical window, copper and dielectric options, terminals, cooling and validation criteria.

Method references

These sources support the engineering tradeoff only; they do not prove PROMAGTECH sample performance.

Related engineering resources