Can an inductor overheat below its stated rated current?
Yes. A current rating is tied to a defined test condition. Application ripple, switching frequency, ambient temperature, nearby heat, airflow, mounting and AC or core losses can make the real temperature rise higher even when measured current is below the stated value.
Should I compare average, RMS or peak current with the rating?
Use RMS current for the winding-heating baseline, peak current for loaded-inductance or saturation review, and the full ripple waveform plus switching frequency for AC winding and core loss. One current number cannot replace all three checks.
Why can low-frequency DCR predict too little heat?
The I-squared-R estimate captures the DC winding baseline but not frequency-dependent skin and proximity effects or magnetic core loss. Those additional losses depend on waveform, frequency, construction and material.
Can an infrared camera prove the winding temperature?
No. Infrared imaging maps surface temperature and requires emissivity control. Pair it with a contact hot-spot method and a winding-average method such as resistance change when the project requires a defensible thermal result.
What test conditions must accompany a temperature-rise result?
Record the current waveform, switching frequency, ambient, airflow, mounting, cooling interface, adjacent heat sources, sample revision, sensor method, emissivity or resistance timing, and the thermal-equilibrium criterion.
Does this troubleshooting guide prove a PROMAGTECH inductor rating?
No. This page is a diagnostic method. Calculation, simulation, sample measurement, continuous thermal validation and production acceptance remain separate project-specific evidence states.